Your chimney failed its Level 2. Here is what the findings mean.

Get the findings priced

The findings that fail most often

These are the items we see on failed Level 2 reports in Pasadena and the neighbouring cities, roughly in the order they turn up.

  • No cap, or a cap rusted through, leaving the flue open to rain and embers
  • Water entering at the roofline metal, with stains inside to match
  • A cracked or broken crown
  • Flue tiles cracked, out of line, or with joints washed out
  • A damper that will not close or has rusted loose in its frame
  • No cricket on a wide stack that faces up the slope
  • Wood trim or framing too close to the opening or the flue

What each finding means and the usual fix

An open flue lets rain fall onto the smoke shelf and damper and lets embers out on windy nights. The fix is a fitted cap fastened to the tile or crown. Roofline leaks come from metal that has lifted or was never let into the mortar; the fix is new counter metal cut into the joints, with repointing where those joints are weak.

A cracked crown lets water into the core of the chimney. Fine cracks can take a coating, and a broken slab gets recast. Damaged flue tiles mean exhaust and heat can escape into the masonry, and the usual fix is a stainless liner run from the firebox to the top. A failed damper is replaced, or a sealing damper is fitted at the top of the flue. A wide stack facing uphill gets a cricket so water no longer piles against it. Clearance problems are fixed by moving or replacing the combustible material.

Some owners decide the wood fireplace is not worth the liner work and switch to a gas insert, which runs its own vent up the chimney. That is a valid route, and we price it alongside the repair so you can compare.

Why water comes first

Most findings on a failed report share a cause: water. Rain through an open flue rusts the damper. Water at the roofline soaks the brick. Years of both wash out flue joints. Fixing the liner while the leak is still active means the new work starts getting wet on day one.

So we close the water openings first, then deal with the flue and the firebox. The written plan lists the work in that order, with what is urgent for safe use marked separately from what can wait.

Findings from another company's report

Many of the failed reports we see were written by someone else. We work from them, but we confirm each finding ourselves before quoting, because a figure built on someone else's photos can miss what changed since. If we disagree with an item, we say so and show why.

Prices for the usual fixes

These are our published ranges. A cap is quoted after we measure. Where your house falls depends on the size of the chimney, the roof and what the visit confirms.

Water entry traced and closed
$525 to $3,150
Diverter ridge on the uphill face
$420 to $945
Diverter ridge plus new roofline metal
$630 to $1,600
Switch to gas inside the masonry opening
$2,650 to $5,250
Camera recheck once repairs are done
$370
Fitted top over an open flue
Quoted after we measure

Crown work, relining, dampers, chase lids and roofline metal on its own have no list price. Each gets a written figure for your chimney once we have seen it.

Questions after a failed inspection

Does a failed Level 2 mean the fireplace cannot be used?

Not always. Some findings, like a missing cap, need fixing but do not make the fireplace dangerous today. Others, like a cracked liner or a blocked flue, do. The plan we write marks which is which.

Must everything on the report be fixed at once?

No. Safety items and active leaks come first. Other items can be planned over time, and the written plan shows the order and the price of each part where we publish one.

Is a liner the usual answer for damaged flue tiles?

In most cases, yes. A stainless liner runs inside the old flue and carries the exhaust past the damage. Where the masonry around the flue has failed as well, rebuilding part of the chimney may be needed first.

Can you work from a report another company wrote?

Yes. Send the list of findings when you book. We check each one on site before quoting.

Will you film the flue again after the repairs?

If you want a record for a sale, a lender or an insurer, a recheck is priced as a Level 2 at $370.

Holding a failed report?

Use the contact page to list the findings and the address. We will confirm them on site and put the repairs in order, with prices where we have them.

Call (626) 557-0360