The safety items we record in every unit with a fireplace

Plan a building round

The safety items

Every unit check covers the same list, so the records line up across a building and from one year to the next.

  • Flue open and drawing, with no nest, debris or collapsed tile blocking it
  • Damper opens fully and closes, or on gas units is fixed open where it should be
  • Firebox sound, with no open joints or cracks that let heat reach framing
  • Gas units: pilot and burner flame, vent path and any soot staining around the opening
  • Hearth and clearance from the opening to mantels, trim and furniture
  • Whether a carbon monoxide alarm is present in the unit
  • Water: stains, rust, damp smells or salt bloom that point to an opening above

Carbon monoxide warning signs

Carbon monoxide from a fireplace usually comes from exhaust that is not leaving the way it should. We look for the signs of that: soot on the wall or hood above the opening, a gas flame that has turned soft and orange, a vent pipe that has separated, or a flue partly closed by debris. Each one is recorded with where it is and what it suggests.

Water plays a part here more often than managers expect. Rain coming down an open flue rusts gas vents and loosens tile, and the debris drops to where it can block the exhaust. That is why a missing cap on the roof shows up in a tenant safety record.

We note whether an alarm is present. We do not test alarms or certify a unit's compliance with any law. The owner's duties for alarms stay with the owner.

One record per fireplace

Each fireplace gets its own dated page: unit number, fuel type, the items above, photos and a plain call on whether it is fine to use. A cover sheet lists the whole building at a glance, with any unit that should not be used shown first. Managers file these for owners, boards and insurers as they see fit.

When a unit needs more than a visual check

If a unit shows signs that the visual check cannot see past, such as a tenant reporting smoke in the room, water inside the firebox or damage after a quake, we recommend a Level 2 with a camera for that flue. Wood-burning units that have heavy deposits get a sweep. Both are priced on the same per-fireplace basis, and only the units that need them get them.

Per-fireplace pricing

The total for a building follows the number of fireplaces checked. Follow-up work is only added for the units that need it.

Safety check, each fireplace
$52
Camera follow-up on a flagged flue
$370
Wood-burning unit swept
from $395

Repairs found during the round, such as caps or leak repairs, are listed in the report with their prices where we publish one.

Manager and board questions

What happens if a unit is not safe to use?

We tell the manager before we leave the building and mark that unit at the top of the cover sheet, with the reason. We recommend it is not used until the item is fixed.

Do you test carbon monoxide alarms?

No. We record whether an alarm is present in the unit. Testing and compliance stay with the owner or manager.

Can the board or an insurer keep the records?

Yes. The records belong to whoever booked, and you can share them with anyone you choose. We also send copies to anyone listed on the request.

Our building has a roof leak near a chimney. Is that part of the round?

We note any water signs in each unit and at the roof. Tracing and repairing a leak is a separate job, priced from our leak repair range of $525 to $3,150.

Do gas and wood fireplaces get the same check?

The list covers both. Gas units get the flame, pilot and vent items, and wood units get the firebox and deposit items. The price per fireplace does not change.

A building full of fireplaces to check?

Send the building list and how many fireplaces each one has through the contact page. We will come back with a visit plan and a total.

Call (626) 557-0360